The Ultimate Guide to Fully Automated Biochemistry Analyzers for African Laboratories

The Ultimate Guide to Fully Automated Biochemistry Analyzers for African Laboratories


Introduction

In the fast-evolving field of medical diagnostics, Fully Automated Biochemistry Analyzers have become an essential tool for laboratories worldwide. These machines enhance efficiency, accuracy, and productivity, making them a crucial investment for clinical settings. If you are in Africa and looking for a reliable clinical chemistry analyzer, this guide will help you make an informed decision.

  • What is a Fully Automated Biochemistry Analyzer?

A Fully Automated Biochemistry Analyzer is an advanced medical device used in clinical laboratories to conduct biochemical tests on blood, urine, and other body fluids. These analyzers perform multiple tests simultaneously, reducing human error and improving diagnostic accuracy.

  • Why African Laboratories Need Fully Automated Biochemistry Analyzers?

1. High Accuracy and Reliability
Modern biochemistry analyzer machines provide precise results, reducing the chances of misdiagnosis.

2. Increased Efficiency and Speed
Unlike manual testing, automatic biochemistry analyzers process hundreds of samples within a short time, optimizing workflow in busy hospitals and diagnostic centers.

3. Cost-Effective for Growing Healthcare Needs
With the demand for affordable healthcare solutions in Africa, investing in an affordable biochemistry analyzer for African laboratories ensures cost savings and improved healthcare services.

  • Key Features to Look for in a Biochemistry Analyzer

When selecting a clinical chemistry analyzer, consider the following factors:

– Throughput Capacity – Choose an analyzer that meets your lab’s workload (e.g., 100-600 tests per hour).
– Sample Volume Requirements – Some analyzers require minimal sample volume, making them ideal for pediatric and geriatric patients.
– Ease of Operation – User-friendly interfaces and automation reduce the need for skilled technicians.
– Connectivity Options – Advanced machines offer LIS (Laboratory Information System) integration for seamless data management.
– Maintenance and Support – Consider manufacturers that provide reliable technical support and spare parts.

For instance, compact models like the Model No.: XR210 Fully Automated Biochemistry Analyzer from XIN RUI MEDICAL EQUIPMENT TECHNOLOGY CO., LTD are an excellent choice for laboratories requiring efficiency in a space-saving design. This model combines high accuracy with ease of use, making it suitable for various clinical applications. More details about the Model No.:XR210 can be found from(https://www.xinrea.com/306.html).

  • How to Choose the Best Biochemistry Analyzer for Your Laboratory

– Define Your Needs – Assess your laboratory’s patient volume and required test parameters.
– Compare Features and Pricing – Research different models and manufacturers for the best value.
– Check Manufacturer Reputation – Opt for established brands with positive reviews and local support.
– Evaluate After-Sales Support – Ensure warranty, training, and service contracts are available.

Conclusion

Investing in a high-performance biochemistry analyzer for medical labs is a game-changer for laboratories in Africa. These machines enhance diagnostic accuracy, improve efficiency, and reduce long-term operational costs. Whether you are setting up a new laboratory or upgrading existing equipment, selecting the right automatic biochemistry analyzer will elevate your lab’s performance and service quality.

Are you ready to upgrade your laboratory with a state-of-the-art biochemistry analyzer? Contact us today to learn more about our high-quality laboratory solutions.

 

 

 

Viral Dectection Kits

• Adenovirus test
• Rotavirus test
• Rotavirus/adenovirus combination test
• Norovirus (GI/GII) test
• Entamoeba test
• Giardia test
• Occult blood rapid cassette test
• Hemoglobin/transferrin combination test
• Helicobacter pylori stool antigen test
• Calprotectin/lactoferrin combination test
• Calprotectin test
• Lactoferrin test
• Influenza A/B combination test
• Streptococcus A test

Accept customer customization requirements。

Semi-Auto Biochemistry Analyzer

Advantage

  • Semi-auto biochemistry analyzer with incubation
  • Big color screen with high resolution and capacitive touch
  • Updated liquid system with diaphragm pump and valve
  • User-friendly operational interface
  • Open reagent system

Technical Specification

Analytical Mlodes:1 point end, 2 point end(Sample blank), Kinetics, Fixed-time.
Filters 7 filters:340nm,405nm,450nm,505nm,546nm,578nm, 630nm,2more optional
light: Durable Tungsten Halogen Lamp [10 watts consumption)eDisplay: 1024*600 Color LcD with capacitive touch screen
Thermal Printer: Built-in thermal printer
Temperature: 25,30,37 degrees centigrade, Room temperature.

Photometric accuracy: 0~0.2A 0.001Abs
Wavelength accuracy:±nm
Repeatability:<1%
stability:<0.005Abs/10min
Linearity:0-1.5A<1.096
Incubator: Built-in muiti-function incubator
Incubator Temperature: 37 degrees centigrade
Reagent system: Open
Memory: Memory stores minimum 190000 results

Power: 110-230 VAC, Line frequency: 50-60 Hz.& Fxternal Universal
SMiPS Adapter
Operational tem,& humidity: 8–39 degrees centigrade; s90% humidityeCartoon Dimension:53 41*31(cm}, Weight: 8.5kg

After-sales maintenance video

  • Voltage Adjustment

  • Check the optical path position

  • Check photoelectric AD value

  • Chek the sample proble

  • Dredge adding sample

  • Replace adding sample probe

  • Replace mainboard

  • Replace syringe

  • Replace bulb

  • Replace the liquid level detection board

  • Replace the liquid pump A3

  • Replace the liquid pump A4

  • Replace the motor drive board

  • Replace the photoelectric plate

  • Replace the sensor

  • Replace the two-way value

  • Replace waste liquid pump

  • Sample probe striker-wipe sensor

 

 

 

 

Clinical Chemistry Analyzer for pet Model No.: XR210

Technical Parameters
Type: Full automatic/random option/emergency first
Test Speed: 210tests/hour
Test method : End point, Kinetic, Fixed time, support STAT
Cleaning Method:With 7 segment 15 steps auto-washing to guaranty cleaning and avoid carryover.
Wavelength: 340nm-630nm,customizable.
Reagent volume: 20~400ul, step by 1 ul.
Sample volume: 2~40ul, step by 1ul
Reagent tray: 54 reagent position, support various primary sample tube
Sample tray: 45 sample position , support various primary sample tube
Reaction tray: Direct solid-heating system, 135 reaction cuvettes with auto-washing function ,minimum reaction volume 140ul.
Alarm:Automatic alarm for water lacking and waste water overflow(optional)
Light source: Halogen tungsten lamp. Life is more than 2000 hours
Absorbance: 0~4.0Abs(10mm conversion)
Resolution: 0.0001Abs
Calibration: Linear( one-point, two-point and multi-point ), Logit-log 4P,Spline
Water consumption: ≤4L/ hour
Operation System: Windows7/8, Windows XP, etc
Data storage: Auto save, auto backup.
Print format: Customized .
Power supply: A.C 100~240V , 50~60Hz , auto adaption
Dimension:600mm*580mm*630mm(Length * Width * High)

Fully Auto 3-Part Hematology Analyzer

– Advanced flow sweeping technology Ensure the accuracy of PLT.
– HD color display, sensitive touch.
– Support wearing rubber gloves to operate.
– Only two reagents are required to measure the sample Low consumption of reagents for a single test.
– One-click test, one-click elimination of obstacles.
– Single interface presents all daily information.

Product Specifications

Measurement Techniques

Classical electrical impedance measurement technique
Cyanide-free HGB measurement technology

Measurement mode

Venous whole blood mode
Pre-diluted peripheral blood mode
Anticoagulated peripheral whole blood mode

Measurement speed/volume of blood

60 samples/hour
≤10 µl

LCD touch screen

10.4 inches
Capacitive touch screen

Storage capacity

Storage more than 100,000 copies
(including histogram, patient information)

Measurement items

WBC, Lym#, Mid#, Gran#, Lym%,
Mid%, Gran%, RBC, HGB,HCT, MCV,
MCH, MCHC, RDW-CV, RDW-SD,
PLT, MPV, PDW, PCT, P-LCR, P-LCC

Result output / expansion interface

Built-in thermal printer or external printer
4 USB ports, 1 network port, 1 serial port
Two-way LIS system supports HL7 protocol
Built-in RFID reader and writer (optional)

Usage Environment

Wide range input: a.c. 100-240V,50/60Hz
Temperature: 10-30℃ Humidity: 20-85%
Atmospheric pressure: 70-106KPa
Altitude: ≤3500m

Size/Weight

WXHXD.
315mmX416mmX411mm
Approx. 26kg

96 channel nucleic acid extractor

Technical Parameters

Sample type
Whole blood, serum, plasma, throat swab, puncture fluid, etc.

Nucleic acid extraction method
Automated magnetic bead method

Wide processing volume range
Can extract samples with a volume of 20 – 1000 μl

High magnetic bead recovery rate
Magnetic bead recovery rate is above 98%

High heating temperature accuracy
Two independent heating modules, customize the lysis temperature according to needs

Multi-speed oscillation mixing
Multiple speeds are adjustable, and the oscillation amplitude can be adjusted according to the reagent volume

Complete internal program
Built-in 12 sets of mode programs, you can add or import parameters independently

Unique safety door design
Automatically pause the program after the safety door is opened, and continue to run the program after the safety door is closed to avoid cross infection

Built-in air duct design
Unique built-in air duct design can avoid cross infection

Power failure safety protection
Support power failure protection function, continue to run after power is restored

Well plate type
96-well plate, can be adapted to a single six-tube reagent kit

Number of magnetic rods:
96

Purification sensitivity:
10IU/ML sample positive detection rate>95%

Lysis temperature:
25℃-90℃

Sample throughput
96 sample channels

Extraction time
15-60 minutes/round (determined by the reagents used)

Extraction well difference
CV ≦3%

Screen operation
7-inch high-resolution color touch screen

Instrument expansion interface:
Standard RS232 interface

Disinfection method:
Built-in UV lamp disinfection

Exhaust method:
Fan

Ambient temperature:
10℃–40℃

Relative humidity
80%

Power supply:
AC110-220V, 50/60HZ

32/48 channel nucleic acid extractor

Technical parameters

Sample type
Whole blood, serum, plasma, throat swab, puncture fluid, etc.

Nucleic acid extraction method
Automated magnetic bead method

Wide processing volume range
Can extract samples with a volume of 20 – 1000 μl

High magnetic bead recovery rate
Magnetic bead recovery rate is above 98%

High heating temperature accuracy
4/6 independent heating modules, customized lysis temperature according to needs

Multi-speed oscillation mixing
Multiple speeds are adjustable, and the oscillation amplitude can be adjusted according to the reagent volume

Complete internal program
Built-in 10 sets of mode programs, you can add or import parameters independently

Unique safety door design
Automatically pause the program after the safety door is opened, and continue to run the program after the safety door is closed to avoid cross infection

Built-in air duct design
Unique built-in air duct design can avoid cross infection

Power failure safety protection
Support power failure protection function, continue to run after power is restored

Well plate type
96-well plate, can be adapted to a single six-tube reagent kit

Number of magnetic rods:
6 rows, 48

Purification sensitivity:
The positive detection rate of 10IU/ML samples is >95%

Lysis temperature:
25℃-90℃

Sample throughput
32/48 sample channels

Extraction time
15-60 minutes/round (determined by the reagents used)

Extraction well difference
CV ≦3%

Screen operation
7-inch high-resolution color touch screen

Instrument expansion interface:
Standard RS232 interface

Disinfection method:
Built-in UV lamp disinfection

Exhaust method:
Fan

Ambient temperature:
10℃–40℃

Relative humidity
80%

Power supply:
AC110-220V, 50/60HZ

Dimensions
398mm×446mm×431mm

Weight:
35KGS

Clinical Chemistry Analyzer Model No.: XR420B

Technical Parameters
Type: Full automatic/random option/emergency first
Test Speed: 450tests/hour
Test method : End point, Kinetic, Fixed time, support STAT
Cleaning Method:With 9 segment 21 steps auto-washing to guaranty cleaning and avoid carryover.
Wavelength: 340nm-800nm,customizable.
Reagent volume: 20~400ul, step by 1 ul.
Sample volume: 2~40ul, step by 1ul
Reagent tray: 100 reagent position with onboard cooling system.
Sample tray: 128 sample position , support various primary sample tube
Mixer: High precision mixer station to ensure excellent reaction conditions
Reaction tray: Direct solid-heating system, 135 reaction cuvettes with auto-washing function ,minimum reaction volume 140ul.
Alarm:Automatic alarm for water lacking and waste water overflow(optional)
Light source: Halogen tungsten lamp. Life is more than 2000 hours
Absorbance: 0~4.0Abs(10mm conversion)
Resolution: 0.0001Abs
Calibration: Linear( one-point, two-point and multi-point ), Logit-log 4P,Spline
Water consumption: ≤15L/ hour
Operation System: Windows7/8, Windows XP, etc
Data storage: Auto save, auto backup.
Print format: Customized .
Power supply: A.C 100~240V , 50~60Hz , auto adaption
Dimension: 1308mm*788mm*1106mm(Length * Width * High)