Semi-Auto Biochemistry Analyzer

Advantage

  • Semi-auto biochemistry analyzer with incubation
  • Big color screen with high resolution and capacitive touch
  • Updated liquid system with diaphragm pump and valve
  • User-friendly operational interface
  • Open reagent system

Technical Specification

Analytical Mlodes:1 point end, 2 point end(Sample blank), Kinetics, Fixed-time.
Filters 7 filters:340nm,405nm,450nm,505nm,546nm,578nm, 630nm,2more optional
light: Durable Tungsten Halogen Lamp [10 watts consumption)eDisplay: 1024*600 Color LcD with capacitive touch screen
Thermal Printer: Built-in thermal printer
Temperature: 25,30,37 degrees centigrade, Room temperature.

Photometric accuracy: 0~0.2A 0.001Abs
Wavelength accuracy:±nm
Repeatability:<1%
stability:<0.005Abs/10min
Linearity:0-1.5A<1.096
Incubator: Built-in muiti-function incubator
Incubator Temperature: 37 degrees centigrade
Reagent system: Open
Memory: Memory stores minimum 190000 results

Power: 110-230 VAC, Line frequency: 50-60 Hz.& Fxternal Universal
SMiPS Adapter
Operational tem,& humidity: 8–39 degrees centigrade; s90% humidityeCartoon Dimension:53 41*31(cm}, Weight: 8.5kg

Clinical Chemistry Analyzer Model No.: XR420B

Technical Parameters
Type: Full automatic/random option/emergency first
Test Speed: 450tests/hour
Test method : End point, Kinetic, Fixed time, support STAT
Cleaning Method:With 9 segment 21 steps auto-washing to guaranty cleaning and avoid carryover.
Wavelength: 340nm-800nm,customizable.
Reagent volume: 20~400ul, step by 1 ul.
Sample volume: 2~40ul, step by 1ul
Reagent tray: 100 reagent position with onboard cooling system.
Sample tray: 128 sample position , support various primary sample tube
Mixer: High precision mixer station to ensure excellent reaction conditions
Reaction tray: Direct solid-heating system, 135 reaction cuvettes with auto-washing function ,minimum reaction volume 140ul.
Alarm:Automatic alarm for water lacking and waste water overflow(optional)
Light source: Halogen tungsten lamp. Life is more than 2000 hours
Absorbance: 0~4.0Abs(10mm conversion)
Resolution: 0.0001Abs
Calibration: Linear( one-point, two-point and multi-point ), Logit-log 4P,Spline
Water consumption: ≤15L/ hour
Operation System: Windows7/8, Windows XP, etc
Data storage: Auto save, auto backup.
Print format: Customized .
Power supply: A.C 100~240V , 50~60Hz , auto adaption
Dimension: 1308mm*788mm*1106mm(Length * Width * High)

Clinical Chemistry Analyzer Model No.: XR420A

Technical Parameters
Type: Full automatic/random option/emergency first
Test Speed: 450tests/hour
Test method : End point, Kinetic, Fixed time, support STAT
Cleaning Method:With 7 segment 15 steps auto-washing to guaranty cleaning and avoid carryover.
Wavelength: 340nm-800nm,customizable.
Reagent volume: 20~400ul, step by 1 ul.
Sample volume: 2~40ul, step by 1ul
Reagent tray: 72 reagent position with onboard cooling system.
Sample tray: 68 sample position , support various primary sample tube
Mixer: High precision mixer station to ensure excellent reaction conditions
Reaction tray: Direct solid-heating system, 135 reaction cuvettes with auto-washing function ,minimum reaction volume 140ul.
Alarm:Automatic alarm for water lacking and waste water overflow(optional)
Light source: Halogen tungsten lamp. Life is more than 2000 hours
Absorbance: 0~4.0Abs(10mm conversion)
Resolution: 0.0001Abs
Calibration: Linear( one-point, two-point and multi-point ), Logit-log 4P,Spline
Water consumption: ≤6L/ hour
Operation System: Windows7/8, Windows XP, etc
Data storage: Auto save, auto backup.
Print format: Customized .
Power supply: A.C 100~240V , 50~60Hz , auto adaption
Dimension: 1047mm*599mm*1134mm(Length * Width * High)

Clinical Chemistry Analyzer Model No.: XR320

Technical Parameters
Type: Full automatic/random option/emergency first
Test Speed: 320tests/hour
Test method : End point, Kinetic, Fixed time, support STAT
Cleaning Method:With 7 segment 15 steps auto-washing to guaranty cleaning and avoid carryover.
Wavelength: 340nm-800nm,customizable.
Reagent volume: 20~400ul, step by 1 ul.
Sample volume: 2~40ul, step by 1ul
Reagent tray: 60 reagent position with onboard cooling system.
Sample tray: 60 sample position , support various primary sample tube
Mixer: High precision mixer station to ensure excellent reaction conditions
Reaction tray: Direct solid-heating system, 135 reaction cuvettes with auto-washing function ,minimum reaction volume 140ul.
Alarm:Automatic alarm for water lacking and waste water overflow(optional)
Light source: Halogen tungsten lamp. Life is more than 2000 hours
Absorbance: 0~4.0Abs(10mm conversion)
Resolution: 0.0001Abs
Calibration: Linear( one-point, two-point and multi-point ), Logit-log 4P,Spline
Water consumption: ≤5L/ hour
Operation System: Windows7/8, Windows XP, etc
Data storage: Auto save, auto backup.
Print format: Customized .
Power supply: A.C 100~240V , 50~60Hz , auto adaption
Dimension: 1047mm*599mm*1134mm(Length * Width * High)

Clinical Chemistry Analyzer Model No.: XR220PLUS

Technical Parameters
Type: Full automatic/random option /emergency first
Test Speed: 220tests/hour
Test method : End point, Kinetic, Fixed time, support STAT
Cleaning Method:With 7 segment 15 steps auto-washing to guaranty cleaning and avoid carryover.
Wavelength: 340nm-630nm,customizable.
Reagent volume: 20~400ul, step by 1 ul.
Sample volume: 2~40ul, step by 1ul
Reagent tray: 54 reagent position with onboard cooling system.
Sample tray: 45 sample position , support various primary sample tube
Reaction tray: Direct solid-heating system, 135 reaction cuvettes with auto-washing function ,minimum reaction volume 140ul.
Alarm:Automatic alarm for water lacking and waste water overflow(optional)
Light source: Halogen tungsten lamp. Life is more than 2000 hours
Absorbance: 0~4.0Abs(10mm conversion)
Resolution: 0.0001Abs
Calibration: Linear( one-point, two-point and multi-point ), Logit-log 4P,Spline
Water consumption: ≤4L/ hour
Operation System: Windows7/8, Windows XP, etc
Data storage: Auto save, auto backup.
Print format: Customized .
Power supply: A.C 100~240V , 50~60Hz , auto adaption
Dimension: 566mm*559mm*1180mm(Length * Width * High)

Clinical Chemistry Analyzer Model No.: XR210

Technical Parameters
Type: Full automatic/random option/emergency first
Test Speed: 210tests/hour
Test method : End point, Kinetic, Fixed time, support STAT
Cleaning Method:With 7 segment 15 steps auto-washing to guaranty cleaning and avoid carryover.
Wavelength: 340nm-630nm,customizable.
Reagent volume: 20~400ul, step by 1 ul.
Sample volume: 2~40ul, step by 1ul
Reagent tray: 54 reagent position, support various primary sample tube
Sample tray: 45 sample position , support various primary sample tube
Reaction tray: Direct solid-heating system, 135 reaction cuvettes with auto-washing function ,minimum reaction volume 140ul.
Alarm:Automatic alarm for water lacking and waste water overflow(optional)
Light source: Halogen tungsten lamp. Life is more than 2000 hours
Absorbance: 0~4.0Abs(10mm conversion)
Resolution: 0.0001Abs
Calibration: Linear( one-point, two-point and multi-point ), Logit-log 4P,Spline
Water consumption: ≤4L/ hour
Operation System: Windows7/8, Windows XP, etc
Data storage: Auto save, auto backup.
Print format: Customized .
Power supply: A.C 100~240V , 50~60Hz , auto adaption
Dimension:600mm*580mm*630mm(Length * Width * High)